CL Style Heaters
CL150212-200 | Engine Heater
- HOTSTART CL150208-200 Engine Heater – Weather-Tight Coolant preheater with Thermostat
- Pre-Heat: Diesel and Gas engines, construction equipment, trucks, marine and industrial applications
- Heating Fluid: Engine Coolant, Water, other – No pump needed (thermosiphon principle)
- Engine Displacement: 1350 – 1650 CID (22.1 – 27.0L)
- Volts: 240v – kW: 5.0 – AMPS: 20.8 – 60Hz – Single Phase
- Temperature Range: ON: 80°F (27°C) – OFF 100°F (38°C)
SKU: CL150212200 -
Auto Mains (Utility) Failure Control Modules
DSE7120MKII | Auto Mains (Utility) Failure Control Modules
Auto Mains (Utility) Failure Control ModulesDSE7120MKII | Auto Mains (Utility) Failure Control Modules
OVERALL SIZE
240 mm x 181 mm x 42 mm (9.4” x 6.8” x 1.6”)
PANEL CUTOUT SIZE
220 mm x 160 mm (8.7″ x 6.3″)
MAXIMUM PANEL THICKNESS
8.0 mm (0.3”)
WEIGHT
0.82kg
PRODUCT VARIANTS
7120-01 – 7120 MKII Auto Mains (Utility) Control ModuleSKU: DSE7120MKII -
-
TPS Heaters
TPS202GT12-000 | Engine Heater
- Pre-Heat: Diesel and Gas engines, construction equipment, trucks, marine and industrial applications
- Heating Fluid: Engine Coolant, Water, other No pump needed (thermosiphon principle)
- Engine Displacement: 500 – 700CID (8.2 – 11.5L)
- Volts: 240v – kW: 2 – AMPS: 8.3 – 60Hz
- Temperature Range: ON: 120°F (49°C) – OFF 140°F (60°C)
SKU: TPS202GT12000 -
Automatic and manual with Controller
Transfer Switch 2 pole | 125 Amps
- Manufactured using UL 94V-0 plastics.
- Electrically operated and mechanically held.
- Coil operating voltage: 110 / 220 Vac +/- 20%.
- Monitor Normal & Standby source OV and UV.
- Compact size, light weight and low power consumption.
- Adjustable time delay in OFF position when transferring.
- Designed for cell-phone repeaters, and many industrial and home ATS applications.
- Electrically or manually operated, mechanically held contacts – (Open Transition) with adjustable time in neutral.
SKU: TCS2P125
-
-
AVR | Generic Replacements
Stamford AVR MX321 | Generic
Features include:
- Stability selection & adjustment *Under frequency roll off adjustment
- Dip adjustment *Dwell adjustment
- Droop adjustment *Trim adjustment
- Over excitation adjustment *Over voltage adjustment
- Current limit adjustment *Ramp adjustment
SKU: MX321G -
-
AVR | Generic Replacements
Stamford AVR AS480 | Generic
SENSING and POWER INPUT
- Voltage: 100-264 Vac 1 phase
- Frequency: 50-60 Hz Nominal
OUTPUT
- Voltage: 82 Vdc @ 200 Vac power input
- Voltage: 45 Vdc @ 110 Vac power input
- Current: Continuous 5A
REGULATION
- +/- 1.0%
THERMAL DRIFT
- 0.03% per deg. Change in AVR ambient
SKU: AS480G -
AVR | Generic Replacements
Leroy Somer R250 | Generic
- Power Input: AC 80-140V (50 / 60Hz)
- Maximum output: DC 90V / 6A / 10S
- Detection voltage input: AC 115V
- Voltage regulation rate: ≤ ± 1% External voltage trimming 1K / 2W potentiometer ± 10%
- Voltage regulation +/- 0.5% at steady state and constant speed
SKU: R250G -
AVR | Generic Replacements
Leroy Somer AVR R438 | Generic
Fuse: F1on X1,X2.10A;slow-250V
- Voltage sensing : 5 VA isolated via trans- former • 0-110 V terminals = 95 to 140 V • 0-220 V terminals = 170 to 260 V • 0-380 V terminals = 340 to 520 V for other voltages, a transformer should be used.
- Voltage regulation ± 0.5%
- Normal or rapid response time via jumper ST2 (see below)
- Voltage adjustment via potentiometer P2 or apply a DC voltage of ± 1 V on the terminals of the external potentiometer
- Current sensing: (parallel operation): input S1, S2 intended for 1 C.T. Š 2.5 VA cl1, secondary 1A (optional)
- Quadrature droop adjustment via potentio- meter P1
SKU: R438G -
AVR | Generic Replacements
Leroy Somer AVR R448 | Generic
- Voltage regulation ± 0.5%
- Short circuit capability: 3 x Irated for 10 seconds (AREP or PMG excitation)
- Voltage sensing: 95 to 140 volts (50/60 Hz) or 170 to 260 volts (50/60 Hz) or 340 to 520 volts (50/60 Hz)
- Response time: Normal (1 sec) for ± 20% voltage variation or Rapid (0.3 sec) for ± 20% voltage variation
- Remote voltage adjustment range of: ± 5%
SKU: R448G
Products Grid
Recently Added
Leroy Somer AVR
Leroy Somer AVR R450 | Original
The R450 AVR is supplied in a casing designed to be mounted on a panel with dampers.
Operating temperature: – 30°C to + 65° C. – Storage temperature: – 55°C to + 85°C.
Shocks on the base: 9 g depending on the 3 axes.
Vibrations: less than 10 Hz, 2 mm half-peak amplitude 10 Hz to 100 Hz: 100 mm/s, above 100 Hz: 8 g.
SKU: R450
Stamford AVR
Stamford AVR MX321 | Original
Features include:
Stability selection & adjustment *Under frequency roll off adjustment
Dip adjustment *Dwell adjustment
Droop adjustment *Trim adjustment
Over excitation adjustment *Over voltage adjustment
Current limit adjustment *Ramp adjustment
SKU: MX321
ATS Control Modules
DSE330 | Auto Transfer Switch Control Module
OVERALL SIZE
98 mm x 79 mm x 40 mm (3.9” x 3.1” x 1.6”)
PANEL CUTOUT SIZE
80 mm x 68 mm (3.1” x 2.7”)
MAXIMUM PANEL THICKNESS
8.0mm (0.3”)
WEIGHT
0.16kg
PRODUCT VARIANTS
0330-01 – 330 Auto Transfer Switch Control Module – 12/24 Volt DC Supply
98 mm x 79 mm x 40 mm (3.9” x 3.1” x 1.6”)
PANEL CUTOUT SIZE
80 mm x 68 mm (3.1” x 2.7”)
MAXIMUM PANEL THICKNESS
8.0mm (0.3”)
WEIGHT
0.16kg
PRODUCT VARIANTS
0330-01 – 330 Auto Transfer Switch Control Module – 12/24 Volt DC Supply
SKU: DSE0330-32